From: Confidence modeling with reliability: a systems approach to sustainable energy planning
Pollution control technology | Time period | ||
---|---|---|---|
t = 1 | t = 2 | t = 3 | |
Treatment cost of SO 2 emission ($/tonne) | |||
SAS | 55 | 57 | 59 |
WLS | 45 | 48 | 51 |
LSD | 30 | 33 | 36 |
Treatment cost of NO x emission ($/tonne) | |||
SCR | 55 | 59 | 62 |
SNCR | 35 | 38 | 40 |
Treatment cost of PM emission ($/tonne) | |||
BH | 135 | 140 | 145 |
ESP | 125 | 133 | 140 |
WC | 115 | 125 | 135 |
Allowable emission amounts of pollutants (tonne) | |||
SO 2 | (40, 44, 50)* | (61, 72, 81) | (69, 82, 93) |
NO x | (20, 32, 45) | (31, 47, 61) | (35, 57, 80) |
PM | (0.3, 0.52, 0.7) | (0.45, 0.8, 1.1) | (0.49, 0.89, 1.2) |
Treatment efficiency of pollutants (%) | |||
SAS | (0.85, 0.91, 0.99) | ||
WLS | (0.76, 0.82, 0.9) | ||
LSD | (0.7, 0.77, 0.85) | ||
SCR | (0.8, 0.86, 0.9) | ||
SNCR | (0.5, 0.62, 0.7) | ||
BH | (0.96, 0.975, 0.99) | ||
ESP | (0.95, 0.964, 0.98) | ||
WC | (0.94, 0.958, 0.97) |