Skip to main content

Advertisement

Table 3 Parameters related to CCS technologies

From: An interval mixed-integer non-linear programming model to support regional electric power systems planning with CO2 capture and storage under uncertainty

Electricity generation facilities η i (106kg/PJ) CCS F ij λ ij r ij Cost of installmentCIN it ($106/GW) Cost of operationCOP it ($106/PJ)
t = 1 t = 2 t = 3 t = 1 t = 2 t = 3
PC (i = 1) [38, 40] j = 1 1 [0, 0] [0.85, 0.90] [20, 25] [22, 27] [25, 28] [9, 13] [10, 14] [11, 16]
j = 2 0
j = 3 1 [0.08, 0.1] [0.90, 1.00] [55, 60] [58, 63] [60, 68] [10, 14] [11, 15] [11, 17]
NGCC (i = 2) [22, 25] j = 1 1 [0, 0] [0.85, 0.90] [22, 28] [25, 30] [27, 32] [7, 10] [9, 13] [11, 15]
j = 2 1 [0.05, 0.08] [0.88, 0.93] [30, 35] [32, 37] [35, 40] [8, 11] [11,14] [12, 17]
j = 3 1 [0.07, 0.09] [0.90, 1.00] [28, 33] [30, 35] [32, 38] [7, 11] [10,14] [12, 17]
IGCC (i = 3) [31, 34] j = 1 1 [0, 0] [0.85, 0.90] [22, 27] [25,30] [28, 33] [10, 14] [12, 16] [14, 18]
j = 2 1 [0.09, 0.11] [0.90, 0.95] [42, 47] [45, 49] [48, 50] [11, 15] [12, 16] [15, 19]
j = 3 1 [0.08, 0.10] [0.90, 1.00] [45, 50] [48, 53] [51, 56] [12, 16] [13, 17] [15, 19]
  1. “–” indicates not applicable.